Posts

Showing posts with the label ICM and InfoSewer

Steps in Using RDII Analyst for InfoSWMM, ICM and InfoSewer

Image
Subject:   Steps in Using RDII Analyst for InfoSWMM, ICM and InfoSewer Step 1: Create a Base UH  in the Operation Tab of the Attribute Browser using RDII Analyst (Figure 1) Step 2: Assign a UH to at Least 1 Node Using the Inflow Icon   Step 3: Open Up RDII Analyst and Click on New to Create a RDII Session     Step 4: Define the Flow and Rainfall File      Step 5: Review the Imported Flow Time Series Step 6: Review the Imported Rainfall  Time Series           Step 7: Units and RDII Analyst Dates are Controlled by the Simulation Manager    Step 8: Extract DWF from the Flow Time Series     Step 9: Assign a UH to at Least 1 Node Using the Inflow Icon   Step 10: View the DWF Pattern          Step 11: Create the RDII Time Series           Step 12: View the RDII Time ...

Modeling H2S in InfoSWMM, ICM and InfoSewer

Image
Subject:     Modeling H2S in InfoSWMM, ICM and InfoSewer You can  model   Sulfide  in  InfoSWMM/ICM and InfoSewer  using the  H2S  water quality  modeling  option which uses BOD5 loading at nodes to estimate the  S concentration in the nodes and links of the network using constant network parameters for:   1.        The Reaction Rate Coefficient, 2.        The  Sulfide  Loss Coefficient, 3.        Sulfide  Flux Coefficient, 4.        Temperature in Degrees C, 5.        Soluble  Sulfide  Percentage, 6.        pH for the whole network, and 7.        The Ionization Constant. Relationship between BOD5 and EBOD Figue 1.   The concentation  of  H2S ...

Steps in Using RDII Analyst for InfoSWMM, ICM and InfoSewer

Image
Subject:   Steps in Using RDII Analyst for InfoSWMM, ICM and InfoSewer Steps in Using RDII Analyst for InfoSWMM, ICM and InfoSewer by  dickinsonre Subject:   Steps in Using RDII Analyst for InfoSWMM, ICM and InfoSewer   Step 1: Create a Base UH  in the Operation Tab of the Attribute Browser using RDII Analyst (Figure 1) Step 2: Assign a UH to at Least 1 Node Using the Inflow Icon   Step 3: Open Up RDII Analyst and Click on New to Create a RDII Session     Step 4: Define the Flow and Rainfall File      Step 5: Review the Imported Flow Time Series Step 6: Review the Imported Rainfall  Time Series           Step 7: Units and RDII Analyst Dates are Controlled by the Simulation Manager    Step 8: Extract DWF from the Flow Time Series     Step 9: Assign a UH to at Least 1 Node Using the Inflow Icon   Step 10: View the DWF Pattern ...