Modeling H2S in InfoSWMM, ICM and InfoSewer
Subject: Modeling H2S in InfoSWMM, ICM and InfoSewer You can model Sulfide in InfoSWMM/ICM and InfoSewer using the H2S water quality modeling option which uses BOD5 loading at nodes to estimate the S concentration in the nodes and links of the network using constant network parameters for: 1. The Reaction Rate Coefficient, 2. The Sulfide Loss Coefficient, 3. Sulfide Flux Coefficient, 4. Temperature in Degrees C, 5. Soluble Sulfide Percentage, 6. pH for the whole network, and 7. The Ionization Constant. Relationship between BOD5 and EBOD Figue 1. The concentation of H2S ...