Node Comparison in InfoSWMM and InfoSewer
Note: Node Comparison in InfoSWMM and InfoSewer 1) Is there an option to set the manhole sealing method (i.e. locked or unlocked) in InfoSWMM ? You set the Surcharged depth to a positive value to prevent flooding and keep the pipes under pressure. You will still have flooding once the water surface elevation reaches the maximum depth + surcharge depth. Unlike in InfoSewer the depths are not unlimited. 2) Is defining manhole diameter in InfoSWMM available? You can set the default surface area of a node or make it a storage node . 3) Does InfoSWMM allow me to create parallel pipes with the same attributes similar to InfoSewer ? You can set the number of barrels in the attribute browser of DB Editor in I...