Posts

Showing posts with the label The Importance of Viewing Results at the Proper Time Scale in SWMM5 and InfoSWMM Models

The Importance of Viewing Results at the Proper Time Scale in SWMM5 and InfoSWMM Models

Image
Subject:    The  Importance  of  Viewing   Results  at the  Proper   Time   Scale In SWMM 5 when you are simulating rapidly changing flow – such as pump flows – it is important to  remember that you are only seeing the  results  of the simulation at your selected report  time  step.  Here is an example model with the same number of pump starts for all three simulations (318), the same  average  time  step during the simulation (10 seconds) but different report  time  steps.  The conception of the pump starts is totally different visually depending on the selected report  time  steps.  You should always compare the starts using the pump graphs and the pump summary table.    The percent utilized and the number of pump start ups tells you  the mean pump start length or in this case 153 seconds or 45.1 percent of 30 hours divided by 318 pump starts...