How to Make a SWMM 5 Calibration File from InfoSWMM

How to Make a SWMM 5 Calibration File from InfoSWMM

Subject:  How to Make a SWMM 5 Calibration File from InfoSWMM
 
 
1st Step:  Graph a Link  in InfoSWMM using the Date /Time Format
 
 
2nd Step:  Click on the Report Button and copy the 1st two columns of data
 
 
3rd Step:  Save the  copied columns to a data file, replace the semi colon and add the name of the link  to the top of the data file as shown below
 
4th Step:  Connect the created calibration data file t o the SWMM 5 Calibration Data Link Flow Rate
 
5th Step:  Run the  Simulation and you should see two  graphs on the screen for the designated link
 

EPA SWMM 5 Calibration Files

The EPA SWMM 5 calibration file is only for comparing the following 12 internal variables graphically to either SWMM 4 results, monitored data or some other model results:
  1. Subcatchment Runoff
  2. Subcatchment Washoff
  3. Node Water Depth
  4. Link Flow Rate
  5. Node Water Quality
  6. Node Lateral Inflow
  7. Node Flooding
  8. Groundwater Flow
  9. Groundwater Elevation
  10. Snow Pack Depth
  11. Link Flow Depth
  12. Link Flow Velocity
 
The graph on your SWMM 5 screen can be saved either to the clipboard or an external file for further manipulation of the computed and observed (calibration file data) by using the commands
Edit->Copy To=>Clipboard=>Text or
Edit->Copy To=>File=>Text
Just remember that the computed variable value comes first in the text followed by the observed variable value. For example:
Link 1030 Flow
Series Elapsed Time (hours) Flow CFS
Computed 0.1667 0.0000

Comments

Popular posts from this blog

Orifice and Weir flow calculations

SWMM 5 Error Messages

EMC Washoff in SWMM5