How to Use Trace Upstream, Domain Manager and Facility Manager in InfoSewer to Find the CE
Subject: How to Use Trace Upstream, Domain Manager and Facility Manager in InfoSewer to Find the CE
Subject: How to Use Trace Upstream, Domain InfoSewer does not have table of node continuity errors only an overall continuity error balance. If you have a continuity error then you can use the process of divide and conquer to find the continuity error. Start at the Outlets and using the Trace Upstream command, Do Step 1. Use Trace Upstream Step 2. Once the upstream domain is created use the Domain Manager Step 3. Make the Domain Inactive using Facility Manger (Figure 3) Step 4. Run the network and check the overall continuity error (Figure 4) Step 5. Continue and repeat until you isolate the area that is the main source of the Continuity Error (CE). Figure 1. Trace Upstream Network and Place it in a Domain Figure 2. Use Domain Manager to take out links without nodes Figure 3. Use Facility Manager to Make the Domain Inactive Figure 4. Find and Isolate the Area with the CE. |